Thursday, April 27, 2017

Atwood Power Converter Charger Installation Instructions classAcustoms









 Atwood Power Converter Charger Installation Instructions classAcustoms


Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101

Friday, April 21, 2017

NEW RecPro BLACK RV CAMPER TRAILER MOTORHOME PADDLE ENTRY DOOR LOCK LATCH HANDLE KNOB DEADBOLT Questions classacustoms

NEW RecPro BLACK RV CAMPER TRAILER MOTORHOME PADDLE ENTRY DOOR LOCK LATCH HANDLE KNOB DEADBOLT

Will this lock fit my unit?

I can only verify the information on the item sold by classAcustoms

You will need to compare your current unit or available measurements with the measurements on the item.

Rough Overall Dimensions: 4 5/16” x 3 1/2”
Rough Cut-out Opening: 3 3/8” x  2 1/2”





Rough Overall Dimensions: 4 5/16” x 3 1/2”
Rough Cut-out Opening: 3 3/8” x  2 1/2”



FIC Travel Trailer Lock Deadbolt 43610 RV Door Lock w/ Deadbolt classacustoms


Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101

Wednesday, April 19, 2017

14" RV Roof Vent Replacement Screen Frame - White B0038YGUN6 Heng's 90106-C1 JRP1124R classAcustoms


This is a screen for the 14" Heng's RV Roof Vent.

Older RV Roof Vents will not have the same measurements and the screen will not fit.
This screen will not fit Ventline vents.

Please look at measurements on the screen before purchasing.


Heng's 90106-C1 Measurements on outer edges of screen: 13" x 13" 







You will need to check the spacing on the handle of your current vent unit, older vents will not match-up to the screen.

Heng's 90106-C1 Roof Vent Screen Frame, 14" x 14" - White B0038YGUN6
Screen Hole for Crank Handle
From Outer Most Edge into Unit: 4 1/2"



Heng's 90106-C1 Roof Vent Screen Frame, 14" x 14" - White B0038YGUN6
Screen Hole for Crank Handle
From Inner Edge into Unit: 3 1/2"



Heng's 90106-C1 Roof Vent Screen Frame, 14" x 14" - White B0038YGUN6  classAcustoms
Heng's JRP1124R 14" White Radius Corner Screen Jensen Roof Vent


Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101


Tuesday, April 11, 2017

Flojet 12v Water Pump 2.9 GPM Model #035261 Installation Booklet classAcustoms


CLASS A CUSTOMS NO LONGER SELLS 
FLOJET 115 VOLT WATER PUMPS







Flat Rate Economy Shipping to the lower 48 Contiguous US Only by USPS Mail

Features & Specifications:
Made by Flojet Model#03526144 / R3526144*
12 volt - You can not put this in a house or plug into a wall - 110/115/220 volt will damage the unit.
4.4 Amp Draw @ 10 PSI
7.5 Amp Draw @ 50 PSI
2.9 Flow GPM
Max PSI 50 Pressure Switch
Built-in Bypass Less Pulsation
Self-priming up to 9 feet suction lift
Run Dry Pump able to run dry without damage
Soft Noise Absorbing Mounts
Snap–in Port Fittings - ½” Fittings included, see photos
CAN NOT be used with accumulator tank
Corrosion Resistant Materials
Meets ISO 8846 (Ignition protection)
Motor Permanent Magnet, Ball Bearing
Pump Three chamber diaphragm design
Totally Enclosed CE Models are fully suppressed.
Includes a Flojet Strainer Model # 01740300
Fittings Included:
2 - 20381000 Pump Port x ½” Male Qest. Straight
1 - 20381009 Pump Port x ½” Hose Barb 90 deg. Elbow

1 - 20381002 Pump Port x ½” Hose Barb Straight
CAUTION: Pump surface will get hot to the touch if operated for extended periods of time under pressurized conditions. Pump will shut off to cool down.
These pumps are for fresh water not pond, lake or sea water.





INSTALLATION INSTRUCTIONS
Step 1: Remove shipping plugs from pump ports. Some water from factory testing may spill out.
Step 2: Connect fitting supplied with the pump the the RV’s plumbing. Use ½” I.D. Flexible hose as shown. Use hose clamps on the slip-on barb hose connectors.
Step 3: Slide rubber mounts fully into mounting tracks.
Step 4: Mount plumbing vertically, with the pump head down or horizontally in an accessible location. If mounting vertically, motor up, attach mounts first then pump head mounts, while supporting weight of pump.
Step 5: Install inlet A and Discharge B port connectors. Firmly push clips C forward to lock port connectors in place.
Step 6: Install a Flojet Strainer in an accessible location (for cleaning and inspecting) before the pump between the tank and the water pump. This strainer or equivalent is required for pump warranty to be valid.


WIRING INSTRUCTIONS
12 volt - You can not put this in a house or plug into a wall - 110/115/220 volt will damage the unit.
Step 1: Use 14 gauge stranded wire to 20', 12 gauge to 50' from power source.
Step 2: Use a 10-15 amp rated on-off switch on the (+) positive (red) motor lead.
Step 3: Install a 10 amp fuse protection on the positive lead.




WARNING:
BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM

TROUBLESHOOTING
Failure to Prime - Motor operates, but no pump discharge
• Restricted intake or discharge line
• Air leak in intake line
• Debris in pump
• Punctured pump diaphragm (pump leaks)
• Crack in pump housing
Motor falls to turn on
• Loose wiring connection
• Pump circuit has no power
• Blown fuse
• Pressure switch failure
• Defective motor
Pulsating Flow
• Restricted pump delivery. Check discharge lines, fittings
and valves for clogging or undersizing
Pump Fails to Turn Off After All Fixtures Are Closed
• Empty water tank
• Insufficient voltage to pump (low battery)
• Punctured pump diaphragm (pump leaks)
• Discharge line leak
• Defective pressure switch
Low Flow and Pressure
• Air leak at pump intake
• Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm (pump leaks)
• Defective motor



Winterizing Sanitizing
SYSTEM CARE AND MAINTENANCE
Allowing water to freeze in the system may result in damage to the pump and plumbing system.

Non-Toxic antifreeze for potable water may be used with Flojet pumps. Follow manufacturer's recommendations.
Refer to coach or equipment manufacturer's instructions for their specific winterizing and drainage procedures.

Do not use automotive antifreeze to winterize potable water systems. These solutions are highly toxic and may cause serious injury or death if ingested.

1. Drain the water tank. Open tank drain valve and plumbing drain valves if applicable. You may use the pump to drain the tank by opening all the faucets in the system. Allow the pump to operate until the tank is empty. Do not operate the pump more than 15 minutes continuously.
2. Open all faucets and flush the toilet to purge all the water from the pump and the plumbing system. Run the pump until no water is coming through the faucets. Turn power to the pump off. Be sure that all the water from the drain lines are drained.
3. Remove quick connect inlet and outlet fittings from the pump and turn the pump on to pump out remaining water from the pump head. Be sure to have a catch pan or a rag under the pump to prevent water from spilling onto the RV. Turn the pump off once the plumbing is empty. Leave the fittings disconnected from the pump until the system is ready to be used again. Make a note on your tank filler that the plumbing is not connected.
4. Be sure that all faucets are left open to protect against damage to the plumbing. Portable water systems require periodic maintenance to deliver a consistent flow of fresh water. Depending on use and the environment the system is subject to, sanitizing is recommended prior to storing and before using the water system after a period of storage. Systems with new components, or ones that have been subjected to contamination, should also be disinfected as follows:
NOTE: The sanitizing procedure is in conformance with the approved procedures of RVIA ANSI A119.2 and the US Public Health Service.
1. Use of the following methods to determine the amount of common household bleach needed to sanitize the tank.
1. A) Multiply “gallons of tank capacity” by 0.13; the result is the ounces of bleach needed to sanitize the tank.
1. B) Multiply “Liters of tank capacity” by 1.0; the result is the milliliters of bleach needed to sanitize the tank.
2. Mix into solution the proper amount of bleach within a container of water
3. Pour the solution (water/bleach) into the tank and fill the tank with potable water.
4. Open ALL faucets (hot and cold) allowing the water to run until the distinct odor of chlorine is detected.
5. The standard solution must have four (4) hours of contact time to disinfect completely. Doubling the solution concentration allows for contact time of one (1) hour.
6. When the contact time is completed, drain the tank. Refill with potable water and purge the plumbing of all sanitizing solution.

WARRANTY
FLOJET warrants this product to be free of defects in material and/or workmanship for a period of two years after purchase by the customer from FLOJET. During this two warranty period, FLOJET will at its option, at no charge to the customer, repair or replace this product if found defective in material or workmanship, with a new or reconditioned product, but not to include costs of removal or installation. This is only an overview of our Limited Warranty. If you would like a copy of our warranty, please call or write FLOJET.

RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service for an authorization number. This number must be written on the outside of the shipping package. Place a note inside the package with an explanation regarding the reason for return as well as the authorization number. Include your name, address and phone number.

Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101



Class A Customs Water Tank Warranty Information classacustoms

Class A Customs has always had a 30 day warranty on water tanks.

30 Day Warranty is 30 days of date item is received.

Class A Customs has not told and will not tell customers there is a 1 year warranty on water tanks.

60 days and 365 days is past the warranty time period.



If you have any issues with an item purchased from Class A Customs please follow the checklist below:

Contact us as soon as item is received, it is a 30 Day Return Policy from date item is received.

Shipping Damage: All parts and packing material must be saved as carrier may request it for an investigation. All shipping carriers require photos of the item(s) and box(es).

Manufacturer Defect: The manufacturer requires photos of defective or damaged parts.

Please send multiple photos of both item(s) and box(es):
Clear, large photos of item(s) and box(es) from all angles showing damage
Photo that shows the overall entire item(s) and box(es) not just the damage
Photo showing serial # if available

Once we receive any information from the carrier / manufacturer we will contact you, please be aware this process can take several days and depends on the shipping carrier / manufacturer.

Wednesday, April 5, 2017

Heng's MA1112 Round Flush Table Base RV Table Leg Chrome classAcustoms


You will need to drill a hole into your floor for this to sit down into.






 You will need to drill a hole into your floor for this to sit down into.





Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101



Heng's MA1119 Standard Table Base RV Table Leg Chrome classAcustoms











Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101



Monday, April 3, 2017

NEW DESIGN J116TWH-CN Heng's Range Hood Exterior Exhaust Vent Off White J116AOW-C classacustoms


 Heng's has redesigned the part # J116AWH-C Exterior Wall Vent
used with ducted range hoods.


 Color of vent has an off white, creamy color


Heng's Part #  J116TWH-CN
Exterior Exhaust Vent for Range Hood


 

Flap locks with push tabs


To install the vent you will need to remove the outer cover, be sure to press in the tabs on both sides to release the front cover.




  Be sure to press in the tabs on both sides to release the front cover, bend tabs in do not try to force the cover off or you will break it.


 3/4" is the size of the insert that will go into the trailer wall
If this does not reach through the trailer wall you can trim the inside of the wall with wood or metal.

2 1/2" overall Width of unit including the cover


 12 11/16" is the overall Length of the unit


6 1/16" is overall Height of unit

Screw holes are inset 1/2" from outer edge (this does not include cover)
This is a new design and screw holes may not match your current unit.

Class A Customs
1130 County Road 6 West
Elkhart, IN 46514
 
Call Us: (574) 206-0101