Open Flow: 11.3LPM / 3.0GPM
Amps: 0.46A
Max Amps: 0.78A
Quiet Operation
1. The pump may be mounted in any
position. If mounted vertically, the pump head should be in the down position
to avoid leakage into the motor casing in the event of a malfunction.
2. Secure the feet, but do not compress them.
Over-tightening the securing screws may reduce their ability to dissipate noise
and vibration.
3. Intake hose must be minimum 1/2" (13 mm) ID
reinforced hose. Main distribution line from pump outlet should also be
1/2" (13 mm) ID with branch and individual supply lines to outlets no
smaller than 3/8"(10 mm).
4. Plumb the system using high pressure (2x pump rating),
braided, flexible tubing to minimize vibration/ noise.
5. Do not apply inlet pressure in excess of 30 psi. In
general, try to avoid any inlet pressure completely.
6. Avoid any kinks or fittings which could
cause excessive restrictions.
7. Strainer should be attached to the inlet side.
8. The fittings must be secured to avoid leakage.
9. Use clamps at both ends of hose to prevent air leaks into the
water line.
10. If a check valve is installed in the plumbing, it must have a cracking
pressure of no more than 2 psi.
11. If applying a sealer or plumbing tape, be careful to not
over-tighten, as they may be sucked into pump.
12. This pump should be wired on its own dedicated circuit. Connect the
positive lead (red) to the positive terminal of your battery and the negative
wire (black) to the negative terminal of your battery.
13. In an easily accessible location, install a switch to control
electricity to the pump. Turn the pump off when not used for extended periods
or when the tank is empty.
14. The electrical circuit should be protected with an over-current
protection device (fuse) in the positive lead. This pump requires a 18 amp
fuse.
15. The pump circuit should not include any other electrical
loads.
16. As the water supply pump is non-essential, reference the
wire chart under the electrical information. Be sure to have the correct wire
sizing for the length of wire you are using.
17. After installation, check the voltage at the pump motor.
Voltage should be checked when pump is operating. Full voltage must be
available at the pump motor at all times.
NOTES
1. Flexible potable water hose or PEX tubing is recommended instead of rigid piping at pump. If you choose to use rigid piping, provide a short length of hose between pipe and the pump to avoid noise and vibration.
2. We do not recommend the use of metal fillings. When possible, use the provided plastic fittings.
3. Do not adjust the bypass personally without the help of technician.
4. Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump. Please do maintenance and winterize the pump at appropriate times, especially before and after a period of storage.
5. All 115 VAC and 230 VAC pump motors and systems, MUST be ground per local and stale electrical codes.