NEW DESIGN J116AWH-C Heng's Range Hood Exterior Exhaust Vent Off White J116AOW-C classacustoms


 Heng's has redesigned the part # J116AWH-C Exterior Wall Vent
used with ducted range hoods.


 Color of vent has an off white, creamy color



 

Flap locks with push tabs


To install the vent you will need to remove the outer cover, be sure to press in the tabs on both sides to release the front cover.




  Be sure to press in the tabs on both sides to release the front cover, bend tabs in do not try to force the cover off or you will break it.


 3/4" is the size of the insert that will go into the trailer wall
If this does not reach through the trailer wall you can trim the inside of the wall with wood or metal.

2 1/2" overall Width of unit including the cover


 12 11/16" is the overall Length of the unit


6 1/16" is overall Height of unit

Screw holes are inset 1/2" from outer edge (this does not include cover)
This is a new design and screw holes may not match your current unit.

NEW DESIGN J116AWH-C Heng's Range Hood Exterior Exhaust Vent Off White J116AOW-C

Class A Customs
1130 County Road 6 West
Elkhart, IN 46514

Phone: (574) 206-0101





PLEASE NOTE:

These are 12 volt Range Hoods

You CAN NOT use them in a house, that is 110 volt and will damage the unit.



RV 12 Volt Range Hood Vent Installation Instructions Heng's Ventline Elixir classacustoms


Range Hood - Slope Style like Elixir, Jensen and Ventline.
12 Volt - You can not put this in a house as that is 110 volt, you will damage the unit.
Washable Grease Filter Included
Underside Light, 10W maximum bulb, Helps you see while cooking.
You choose Ductless or Ducted style range hood.

Measurements:
The overall size of this unit is choose 20" / 22" / 24" wide x 18" deep x 5 1/4" tall.
The slope nose allows installation of this unit with cabinets from 12" - 18" deep.
The hole size for the outside duct is 10" x 3".

Photos are of Heng's Brand Range Hoods in Stainless Steel
























RV Range Hood Cooking Exhaust Fan 12 volt MOTOR Heng's 90044-C


For the 12 volt Range Hoods by Heng's
If you are needing a 12 volt Vent Motor that is Part # 90037-C1 which we also sell.

**12 VOLT POWER ONLY 110/115/220 volt such as in a house or generator will damage the unit**
Shaft "half-moon" or "D" shaft - 1/8" Diameter x 1/2" Long
AMP 1.6








**12 volt ONLY 110/115/220 volt such as in a house or generator will damage the unit**


Stainless Steel 300 series 22 gauge
White or Black Durable Powder Coated Paint Resists Scratching and Chipping
Metal, Washable Grease Filter
Two front panel rocker switches for control of the light and fan


Ductless Style Recirculates air
Ducted Style vents out the back of range hood Exterior Duct 10” x 3”


Overall Measurements
20” Range - 20" w x 18" d x 5 ¼” t
22” Range - 22" w x 18" d x 5 ¼” t
24” Range - 24" w x 18" d x 5 ¼” t


Slope nose design allows installation under cabinets from 12"-18" deep



Class A Customs
1130 County Road 6 West
Elkhart, IN 46514


Phone: (574) 206-0101


Flojet Warranty Information on Fresh Water Pumps 12v and 115v classAcustoms

Class A Customs is not the manufacturer of this item, you would need to contact Flojet, information is on the paperwork provided with pump.







Flat Rate Economy Shipping to the lower 48 Contiguous US Only by USPS Mail

Features & Specifications:
Made by Flojet Model#03526144 / R3526144*
12 volt - You can not put this in a house or plug into a wall - 110/115/220 volt will damage the unit.
4.4 Amp Draw @ 10 PSI
7.5 Amp Draw @ 50 PSI
2.9 Flow GPM
Max PSI 50 Pressure Switch
Built-in Bypass Less Pulsation
Self-priming up to 9 feet suction lift
Run Dry Pump able to run dry without damage
Soft Noise Absorbing Mounts
Snap–in Port Fittings - ½” Fittings included, see photos
CAN NOT be used with accumulator tank
Corrosion Resistant Materials
Meets ISO 8846 (Ignition protection)
Motor Permanent Magnet, Ball Bearing
Pump Three chamber diaphragm design
Totally Enclosed CE Models are fully suppressed.
Includes a Flojet Strainer Model # 01740300
Fittings Included:
2 - 20381000 Pump Port x ½” Male Qest. Straight
1 - 20381009 Pump Port x ½” Hose Barb 90 deg. Elbow
1 - 20381002 Pump Port x ½” Hose Barb Straight
CAUTION: Pump surface will get hot to the touch if operated for extended periods of time under pressurized conditions. Pump will shut off to cool down.
These pumps are for fresh water not pond, lake or sea water.





 


INSTALLATION INSTRUCTIONS
Step 1: Remove shipping plugs from pump ports. Some water from factory testing may spill out.
Step 2: Connect fitting supplied with the pump the the RV’s plumbing. Use ½” I.D. Flexible hose as shown. Use hose clamps on the slip-on barb hose connectors.
Step 3: Slide rubber mounts fully into mounting tracks.
Step 4: Mount plumbing vertically, with the pump head down or horizontally in an accessible location. If mounting vertically, motor up, attach mounts first then pump head mounts, while supporting weight of pump.
Step 5: Install inlet A and Discharge B port connectors. Firmly push clips C forward to lock port connectors in place.
Step 6: Install a Flojet Strainer in an accessible location (for cleaning and inspecting) before the pump between the tank and the water pump. This strainer or equivalent is required for pump warranty to be valid.


WIRING INSTRUCTIONS
12 volt - You can not put this in a house or plug into a wall - 110/115/220 volt will damage the unit.
Step 1: Use 14 gauge stranded wire to 20', 12 gauge to 50' from power source.
Step 2: Use a 10-15 amp rated on-off switch on the (+) positive (red) motor lead.
Step 3: Install a 10 amp fuse protection on the positive lead.



WARNING:
BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM

TROUBLESHOOTING
Failure to Prime - Motor operates, but no pump discharge
• Restricted intake or discharge line
• Air leak in intake line
• Debris in pump
• Punctured pump diaphragm (pump leaks)
• Crack in pump housing
Motor falls to turn on
• Loose wiring connection
• Pump circuit has no power
• Blown fuse
• Pressure switch failure
• Defective motor
Pulsating Flow
• Restricted pump delivery. Check discharge lines, fittings
and valves for clogging or undersizing
Pump Fails to Turn Off After All Fixtures Are Closed
• Empty water tank
• Insufficient voltage to pump (low battery)
• Punctured pump diaphragm (pump leaks)
• Discharge line leak
• Defective pressure switch
Low Flow and Pressure
• Air leak at pump intake
• Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm (pump leaks)
• Defective motor


Winterizing Sanitizing
SYSTEM CARE AND MAINTENANCE
Allowing water to freeze in the system may result in damage to the pump and plumbing system.

Non-Toxic antifreeze for potable water may be used with Flojet pumps. Follow manufacturer's recommendations.
Refer to coach or equipment manufacturer's instructions for their specific winterizing and drainage procedures.

Do not use automotive antifreeze to winterize potable water systems. These solutions are highly toxic and may cause serious injury or death if ingested.

1. Drain the water tank. Open tank drain valve and plumbing drain valves if applicable. You may use the pump to drain the tank by opening all the faucets in the system. Allow the pump to operate until the tank is empty. Do not operate the pump more than 15 minutes continuously.
2. Open all faucets and flush the toilet to purge all the water from the pump and the plumbing system. Run the pump until no water is coming through the faucets. Turn power to the pump off. Be sure that all the water from the drain lines are drained.
3. Remove quick connect inlet and outlet fittings from the pump and turn the pump on to pump out remaining water from the pump head. Be sure to have a catch pan or a rag under the pump to prevent water from spilling onto the RV. Turn the pump off once the plumbing is empty. Leave the fittings disconnected from the pump until the system is ready to be used again. Make a note on your tank filler that the plumbing is not connected.
4. Be sure that all faucets are left open to protect against damage to the plumbing. Portable water systems require periodic maintenance to deliver a consistent flow of fresh water. Depending on use and the environment the system is subject to, sanitizing is recommended prior to storing and before using the water system after a period of storage. Systems with new components, or ones that have been subjected to contamination, should also be disinfected as follows:
NOTE: The sanitizing procedure is in conformance with the approved procedures of RVIA ANSI A119.2 and the US Public Health Service.
1. Use of the following methods to determine the amount of common household bleach needed to sanitize the tank.
1. A) Multiply “gallons of tank capacity” by 0.13; the result is the ounces of bleach needed to sanitize the tank.
1. B) Multiply “Liters of tank capacity” by 1.0; the result is the milliliters of bleach needed to sanitize the tank.
2. Mix into solution the proper amount of bleach within a container of water
3. Pour the solution (water/bleach) into the tank and fill the tank with potable water.
4. Open ALL faucets (hot and cold) allowing the water to run until the distinct odor of chlorine is detected.
5. The standard solution must have four (4) hours of contact time to disinfect completely. Doubling the solution concentration allows for contact time of one (1) hour.
6. When the contact time is completed, drain the tank. Refill with potable water and purge the plumbing of all sanitizing solution.

WARRANTY
FLOJET warrants this product to be free of defects in material and/or workmanship for a period of two years after purchase by the customer from FLOJET. During this two warranty period, FLOJET will at its option, at no charge to the customer, repair or replace this product if found defective in material or workmanship, with a new or reconditioned product, but not to include costs of removal or installation. This is only an overview of our Limited Warranty. If you would like a copy of our warranty, please call or write FLOJET.

RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service for an authorization number. This number must be written on the outside of the shipping package. Place a note inside the package with an explanation regarding the reason for return as well as the authorization number. Include your name, address and phone number.  Class A Customs is not the manufacturer of this item, you would need to contact Flojet, information is on the paperwork provided with pump.


Class A Customs
1130 County Road 6 West
Elkhart, IN 46514

Call Us: (574) 206-0101





RV Escape Hatch and Lid classacustoms

What brand of escape hatch do you currently have?
Class A Customs carries Heng's Brand Escape Hatches

The current design of Heng's brand escape hatches will not match older style Heng's escape hatches.

Heng's purchased the Jensen/Elixir brand name some years ago.

The following part numbers and design of the escape hatches are the only Heng's style we carry.


Ventline no longer makes escape hatches, the sizes and hinge assembly are not the same as Heng's, Elixir or Jensen brand, you can not put a Heng's lid on a Ventline escape hatch.




How are Escape Hatches Measured?
The name of the Heng's escape hatches are shortened names to easily identify the escape hatch, it is not the cut-out measurement or the flange measurement.

You will need to verify your cut-out dimension to accurately find the escape hatch you are needing.



Class A Customs
1130 County Road 6 West
Elkhart, IN 46514


Phone: (574) 206-0101





13 x 20 Escape Hatch by Heng’s Part #  31121-C2 - This Escape Hatch has a Plastic Frame
Rough Cut-out Opening Dimensions (this is the hole you will need in your unit)  14 ¼”  X 21"
Exterior Mounting Flange Dimensions (sits on the top of your unit) 16 ¾”  X 23 ¾”  

Lid Measurements 15 ½” x 22 ½”
Lid Only Part # 90007-C1




15 x 22 Escape Hatch by Heng’s Part # 58621-C2
Rough Cut-out Opening Dimensions (this is the hole you will need in your unit) 17 ⅜” X 24 ⅝”   
Exterior Mounting Flange Dimensions (sits on the top of your unit) 19"  X 26 ½”

Lid Measurements 18” x 25”
Lid Only Part # 90008-C1




Rough Cut-out Opening Dimensions (this is the hole you will need in your unit)  19 ¼ "  X 26 ¼ "   
Exterior Mounting Flange Dimensions (sits on the top of your unit) 21"  X 28"

Lid Measurements 19 ½” x 26 ⅜”
Lid Only Part # 90088-C1




Rough Cut-out Opening Dimensions (this is the hole you will need in your unit)  21 ¼ " x 21 ¼ "  
Exterior Mounting Flange Dimensions (sits on the top of your unit) 23"  x 23"

Lid Measurements 21 ½” x 21 ½”
Lid Only Part # 90129-C1



26 x 26 Escape Hatch by Heng’s Part # 68631-C2
Rough Cut-out Opening Dimensions (this is the hole you will need in your unit)  25 1/2" x 25 1/2"
Exterior Mounting Flange Dimensions (sits on the top of your unit) 27 ½ "  x 27 ½ ”

Lid Measurements 26” x 26”
Lid Only Part # 90014-C1



 Heng's "Curl" Style Hinge







Class A Customs
1130 County Road 6 West
Elkhart, IN 46514


Phone: (574) 206-0101